Nitrogen Phosphorus Detector Npd for Gas Chromatograph Gc-7860

Product Details
Customization: Available
Certification: CE, ISO
Gas Control: EPC
Gold Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
20000000 RMB
Plant Area
>2000 square meters
  • Nitrogen Phosphorus Detector Npd for Gas Chromatograph Gc-7860
  • Nitrogen Phosphorus Detector Npd for Gas Chromatograph Gc-7860
  • Nitrogen Phosphorus Detector Npd for Gas Chromatograph Gc-7860
  • Nitrogen Phosphorus Detector Npd for Gas Chromatograph Gc-7860
Find Similar Products

Basic Info.

Model NO.
NPD
Detectors
Fid, Tcd, Ecd, Fpd, Npd
Column Oven Temperature
4-450ºC with Increment of 1ºC
Transport Package
Carton
Trademark
Yoke Instrument
Origin
China
HS Code
9027201100

Product Description

Detector Parameters for GC-7860 Plus/B, GC-7860 E/SE, GC-7860 A/SA

NPD
Limit of detection: (N)<=5×10¯¹²g/s
                  (P)<=5×10¯¹²g/s

ECD
Limit of detection:<=1×10¯14g/s
Linear range: 104
Source: Ni³

FPD
Limit of detection: 5ׯ¹²g/s(S) (S in methyl parathion)
5×10¯¹³g/s (P) (P in methyl parathion)
Linear range: 105(P)  10³(S)
Maximum service temperature: 350ºC
Detection Method: Air-hydrogen flame spectrometry
Optical detector: Top photomultiplier
Multiplier voltage: Max--700V
 
TCD
Adopt semi-diffused structure
Constant current control mode is adopted for power supply
Sensitivity: S>=3000mv.ml/mg
HTCD High sensitivity thermal conductivity detector S>=10000mv.ml/mg; Digital amplification 1, 2, 4, 8 times optional
Baseline Noise: <=10µv
Baseline Drift: <=30µv/30min
Linear: >=105
Carrier gas velocity stability: <=1%
Capillary column connecting parts are optional

FID
The collecting pole adopts the original cylindrical structure and quartz nozzle
Limit of detection:<=3×10¯¹²g/s
Baseline Noise: 5×10¯14A
Baseline Drift: <=1×10¯¹³A/30min
Linear: >=107
Autoignition
 
Detector Parameters for GC-7860 Micro Gas series

FID Detector
Sensitivity: 6×10¯¹²g/s
Linear Range: 107
Program autoignition

TCD Thermal conductivity detector
Sensitivity: S>=3000mv.ml/mg (N-hexadecane/iso-octane)
Baseline Noise: <=10µv
Baseline Drift: <=30µv/30min
Linear: >=105

ECD Electron capture detector
Limit of detection:<=1×10¯14g/s
Linear range: 104
Source: Ni63

FPD Flame photometric detector
Limit of detection:
5ׯ¹²g/s(S) (S in methyl parathion)
5×10¯¹³g/s (P) (P in methyl parathion)

NPD Nitrogen and phosphorus detector
Limit of detection: (N)<=6×10¯¹²g/s
                (P)<=6×10¯¹²g/s


Relative Products:
 
GC-7860 Network-based series Gas Chromatography

GC-7860 Plus/B, GC-7860 E/SE, GC-7860 A/SA and GC-7860 Micro are available.

Feature:
GC-7860 series network-based gas chromatography is a new digital full control gas chromatography. The instrument has fully absorbed the advanced technology of foreign similar products and adopted the leading manufacturing technology to ensure the reliability and trouble-free operation time of the instrument. It can not only maximize the normal operation time, reduce the number of maintenance, and in the structure of more concise and reasonable, simple to learn, easy to operate.

GC-7860 gas chromatography gas circuit control has two modes of manual and electronic gas circuit EPC/EFC control, advanced electronic gas circuit control (EPC/EFC) system, can provide industry users with industry-leading excellent quality and reliable results. The instrument has a unique network remote transmission and control function, so that the instrument in unattended, decentralized detection, centralized control into a reality; Data analysis results can be connected to DCS to complete the statistics, analysis and monitoring of chromatographic component content and improve the automation of the production process.

GC-7860 series gas chromatography is widely used in petrochemical, fine chemical, biological medicine, environmental protection, food hygiene, high purity gas, electricity, wine making, scientific research and education and other fields.

All inlet and detector gas paths for the GC-7860 gas chromatography can be controlled by an electronic gas circuit (EPC/EFC) to provide better retention time and peak area accuracy. Instrument users can set various parameters such as gas flow rate, shunt ratio, external events, automatic sampler, temperature and detector through the reverse control software, and save all parameters of the analysis method. The digital circuit keeps Settings consistent between operators on each run. As a result, users can achieve better retention time reproducibility and more consistent and reliable results.

GC-7860 series network-based gas chromatography can be configured with 6-bit, 15-bit, and 150-bit liquid automatic samplers, and each parameter can be controlled by the reverse control software, which will bring better repeatability and improve work efficiency, while eliminating errors caused by manual samplers.

Solutions:
1. Gas analysis of pressure transformer oil (GB/T 17623-1998, DL/T 722-2000, DL/T 703-1999)
2. Air quality (TVOC, benzene, total hydrocarbon and non-methane total hydrocarbon) analysis (GB/T 50325-2001, GB/T 18883-2002, gb16927-1996); Workshop exhaust gas, flue gas analysis, and VOC, benzene and non-methane total hydrocarbon in flue gas 24 hours uninterrupted online analysis;
3. Natural gas, refinery gas, pyrolysis gas, artificial gas and other industrial gas gas analysis (simple single valve type, wide spectrum process double valve four-column economy type, wide spectrum process three valve four column practical type, wide spectrum process five valve six column high end type, three valve four column TCD type, four valve five column double TCD type, etc. In accordance with GB/T 13610-2003, UOP539, ASTM1945, ASTM D 1946 and GPA2261; Can be customized according to the user's specific samples);
4. Safety gas analysis in underground coal mine gas chromatography (available for 24 hours continuous cycle sampling analysis of 32 points);
5. Water quality analysis (accord with GB/T 5750-2006);
6. Gas, methane analysis (H2, O2, N2, CH4, CO, CO2 six components, unique single valve sequence conversion);
7. Sulfur compounds in natural gas (unique single-valve sequence reversal method for detection of H2S, CSO, SO2 and total sulfur);
8. High purity gas analysis, electronic industrial gas analysis (minimum detectable concentration up to 10ppb);
9. Benzene and toluene in gasoline (accord with ASTM D3606; SH/T 0713-2002);
10. Analysis of oxygen-containing compounds in gasoline (accord with ASTM D4815 and SH/T 0633-1998);
11. Analysis of benzene, toluene and aromatics in gasoline (in accordance with ASTM d5580-1995, SH/ t0693-2000);
12. SOA analysis of hydrocarbon group composition in gasoline (content detection of saturated hydrocarbon, olefin, aromatic hydrocarbon and benzene, using a special olefin adsorption trap; In line with SH/T 0741-2004), PONA analysis of single hydrocarbon in gasoline and CPNA analysis of the composition of carbon family;
13. Simulated distillation gas chromatography (accord with SH/T 0558, ASTM D5307, D3710, D6352, D2887);
14. Blood ethanol analysis (in line with the ministry of public security standard GA/ t105-1995);
15. Cigarette sticks VOC (in line with YC/T 207-2006), drug residue analysis, ethylene oxide in medical devices (in line with GB/T 16886.7-2001), solvent residue detection in packaging materials;
16. Gas chromatography for room temperature gases (CO2, CH4 and N2O, 0.1ppm-100%);
17. Catalytic evaluation, Fischer-Tropsch synthesis, high pressure and high temperature on-line analytical system (system chromatography based on requirements);
18. Process gas chromatography (industrial chromatography), sample pretreatment, analysis cabin construction, multiple flow path sample selection. (up to 32 sample options are supported), etc

Other Products:
Nitrogen Phosphorus Detector Npd for Gas Chromatograph Gc-7860

Nitrogen Phosphorus Detector Npd for Gas Chromatograph Gc-7860
Nitrogen Phosphorus Detector Npd for Gas Chromatograph Gc-7860
Nitrogen Phosphorus Detector Npd for Gas Chromatograph Gc-7860

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier