Model | P811 | P812 | P813 | P814 | P815 | P816 | P817 | P818 | ||
Standard Accessories | Mini magnetic stirrer | √ | ||||||||
Electrode holder | √ | √ | √ | √ | √ | √ | √ | √ | ||
pH composite electrode | √ | √ | √ | √ | ||||||
Cond. electrode (K=1) | √ | √ | √ | √ | ||||||
DO electrode | √ | √ | √ | √ | ||||||
Ion electrode | √ | |||||||||
Temperature probe | √ | √ | √ | √ | √ | √ | √ | √ | ||
Reference electrode | √ | |||||||||
pH buffer solution | √ | √ | √ | √ | ||||||
DO filling solution | √ | √ | √ | √ | ||||||
Membrane cap | √ | √ | √ | √ | ||||||
Cathode polishing paper | √ | √ | √ | √ | ||||||
Power adapter | √ | √ | √ | √ | √ | √ | √ | √ | ||
Manual | √ | √ | √ | √ | √ | √ | √ | √ | ||
Parameters | pH/mV | √ | √ | √ | √ | √ | ||||
ISE | √ | |||||||||
Cond./TDS/Sal./Res. | √ | √ | √ | √ | ||||||
DO | √ | √ | √ | √ | ||||||
Temp. | √ | √ | √ | √ | √ | √ | √ | √ | ||
pH | Measuring range | (-1.999-19.999)pH | √ | √ | √ | √ | √ | |||
Resolution | 0.1/0.01/0.001pH | |||||||||
Accuracy | Electrode: ±0.002pH, Meter: ±0.01pH | |||||||||
Auto calibration | 1, 2, 3 point | |||||||||
Buffer | Europe & USA, NIST, China standards | |||||||||
Input current | ≤1x10-12A | |||||||||
Input impedance | >=3x1012Ω | |||||||||
Stability | ±0.002pH/3h | |||||||||
Temp. compensation | (0-100)ºC, auto or manual | |||||||||
mV | Measuring range | -1999.9mV-0-1999.9mV | √ | √ | √ | √ | √ | |||
Resolution | 0.1mV | |||||||||
Accuracy | ±0.03%FS | |||||||||
pX | Measuring range | (0.000-14.000)pX | √ | |||||||
Resolution | 0.01pX | |||||||||
Accuracy | ±0.02pX | |||||||||
Temp. compensation | (0-100)ºC, auto or manual | |||||||||
Auto calibration | 1, 2, 3, 4, 5 point | |||||||||
Ion Conc. | Measuring range | (0-19990) | √ | |||||||
Resolution | 4 significant figures (scientific notation) | |||||||||
Accuracy | ±0.5% | |||||||||
Cond. | Measuring range | Conductivity: | √ | √ | √ | √ | ||||
(0.00-20.00)uS/cm, (20.0-200.0)uS/cm | ||||||||||
(200-2000)uS/cm, (2.00-20.00)mS/cm | ||||||||||
(20.0-200.0)mS/cm | ||||||||||
(200-20000)mS/cm (k=10) | ||||||||||
TDS: (0-100)g/L | ||||||||||
Salinity: (0-100)ppt | ||||||||||
Resistivity: )0-100)MΩ•cm | ||||||||||
Resolution | 0.01/0.1/1uS/cm, 0.01/0.1mS/cm | |||||||||
Accuracy | Electrode: ±0.5%FS, Meter: ±0.8%FS | |||||||||
Temp. compensation | (0-50)ºC, auto | |||||||||
Electrode constant | 0.1/0.5/1/5/10/50/100cm-1 | |||||||||
Reference Temp. | 25ºC, 20ºC, 18ºC | |||||||||
DO | Measuring range | (0-20.00)mg/L(ppm), (0-200.0)% | √ | √ | √ | √ | ||||
Resolution | 0.1/0.01mg/L(ppm), 1/0.1% | |||||||||
Accuracy | Electrode: ±0.10mg/L, Meter: ±0.40mg/L | |||||||||
Response time | ≤30s(25ºC, 90%response) | |||||||||
Residual current | ≤0.1mg/L | |||||||||
Temp. compensation | (0-45)ºC, auto | |||||||||
Salinity compensation | (0-45)ppt, auto | |||||||||
Pressure compensation | (80-105)kPa, auto | |||||||||
Auto calibration | Air saturated by water, water saturated by air | |||||||||
Electrode type | Polarographic | |||||||||
Temp. | Range | (-10-110)ºC | √ | √ | √ | √ | √ | √ | √ | √ |
Resolution | 0.1ºC | |||||||||
Accuracy | 5-60ºC: ±0.4ºC others: ±0.8ºC | |||||||||
Other | Display | 7-inch colored capacitive touch screen | √ | √ | √ | √ | √ | √ | √ | √ |
Data storage | 1000 sets | |||||||||
Power | 12V/1A | |||||||||
Output | USB, Bluetooth | |||||||||
Ambient Temp. | 15-30ºC | |||||||||
Ambient humidity | ≤85% | |||||||||
IP grade | IP54 | |||||||||
Dimension/N.W. | 215x170x37mm/600g | |||||||||
Shipping size/G.W. | 470x430x72mm/3kg |